Con-Tec Solutions

Industrial Service

Emergency Lighting

BS EN 50172 and BS 5266 compliant emergency lighting for industrial premises — system survey, escape route lighting design, self-contained and central battery installation, annual testing and maintained digital records.

What industrial emergency lighting compliance actually requires

01

A system spread across a large footprint with no central record

Warehouses and manufacturing facilities can have hundreds of emergency luminaires across multiple zones with no centralised test record. DALI-2 addressed systems generate automatic test logs at the panel — eliminating manual torch walks across the entire floor plate.

02

Failed duration tests that delay certification

Failed annual duration tests are common in systems where battery replacement has not been maintained. We carry out a pre-test condition survey to identify aged batteries before the formal annual test — avoiding failed certificates.

03

Escape routes that don't meet lux requirements

Industrial buildings frequently reconfigure their internal layout — which can leave escape route lighting non-compliant without anyone noticing. We resurvey the escape routes against the current layout and re-calculate illuminance at every point.

04

No documentation for your insurer or Fire Risk Assessment

BS EN 50172 requires documented monthly function tests and annual duration tests. We provide these in digital format, accessible immediately for insurance and Fire Risk Assessment review.

NHS
Eric Wright Group
Lancaster University
Bowmer + Kirkland
Conlon Construction
Casey
Barnfield
Caddick
Northern Care Alliance
Manchester Airports Group
NHS
Eric Wright Group
Lancaster University
Bowmer + Kirkland
Conlon Construction
Casey
Barnfield
Caddick
Northern Care Alliance
Manchester Airports Group

Technical detail

Standards & compliance

  • BS EN 50172 — emergency escape lighting systems
  • BS 5266 Part 1 — emergency lighting of premises
  • BS 7671 emergency circuit separation requirements
  • Fire Risk Assessment interface documentation
  • Health & Safety at Work Act — escape route adequacy

System types

  • Self-contained maintained and non-maintained luminaires
  • Central battery systems to EN 50171
  • DALI-2 addressed emergency control systems
  • IP65 rated luminaires for wet and dusty environments
  • High-bay emergency luminaires for large-volume spaces

Testing & records

  • Monthly function test logs (digital format)
  • Annual 3-hour duration test certification
  • DALI automated test scheduling and reporting
  • Battery condition monitoring and replacement scheduling
  • Emergency Lighting Design Certificate production

Electrical works

  • Escape route luminaire installation and relocation
  • Dedicated circuit separation from normal supply
  • Central battery room installation and cabling
  • Exit sign and directional indicator installation
  • Integration with fire alarm and building management
Con-Tec Solutions — industrial emergency lighting installation

The Numbers

Annual duration test

3hr

BS EN 50172 requires an annual 3-hour full duration test of every luminaire — we carry out, witness and certify each test.

Escape route minimum

1lux

Minimum illuminance along the centre line of an escape route under BS EN 50172 — our designs are calculated to achieve this at every measurement point.

Automated test logging

DALI

DALI-2 addressed systems eliminate manual testing walks and generate automatic electronic records — essential across large industrial floor plates.

Why specify Con-Tec

Compliance Maintained, Not Just Installed

01

Pre-test condition surveys

We carry out a battery and luminaire condition survey before the annual duration test — identifying potential failures before they produce a failed certificate.

02

DALI addressed systems for large footprints

For large industrial premises, DALI-2 addressed systems are the only practical way to maintain compliant test records. We design, commission and maintain these systems.

03

Escape route re-survey on layout change

When your floor plan changes, your emergency lighting compliance changes too. We offer a rapid re-survey service whenever internal layout alterations affect escape routes.

04

Digital records on demand

Every test result, maintenance visit and certificate is held digitally and available immediately for insurer, Fire Risk Assessment or regulatory inspection.

01

Condition Survey

Full luminaire and battery condition survey across the premises, producing a written report against BS EN 50172 and BS 5266 requirements.

02

Design & Specification

Escape route illuminance calculations and zone plan produced before any equipment is ordered or repositioned.

03

Installation & Commissioning

Works delivered to programme around your operational schedule, with DALI addressed systems commissioned and verified at completion.

04

Ongoing Maintenance & Testing

Monthly function tests, annual duration tests and digital record management — all under a fixed-price maintenance agreement.

1 / 4

What our clients say

Con-Tec consistently meets the rigour our estates teams expect. Their compliance documentation, site discipline and turnaround on remedial works are exactly what large-scale healthcare contracts require.

Get a Quote

Ready to Start a Project?

We respond to every commercial and industrial enquiry within one working day. Share your scope and programme and we'll come back with lead engineers, approach and a clear cost envelope.

Emergency Lighting | Industrial Electrical | Con-Tec Solutions