Emergency lighting testing, certification and compliance reporting to BS EN 50172 and BS 5266 — monthly function test records, annual 3-hour duration test certification, digital logbook management and DALI automated test reporting.

What emergency lighting compliance reporting actually requires

01

An emergency lighting logbook that has never been maintained

BS EN 50172 requires a documented test record maintained throughout the life of the system. Where no logbook exists, we establish a digital baseline by surveying the current installation and carrying out the first compliant function and duration test — creating a dated compliance record from that point forward.

02

A failed annual duration test

Failed duration tests are most commonly caused by aged batteries or failed luminaires that were not identified during routine monthly function tests. We carry out a condition survey before the scheduled annual test to identify these items in advance.

03

No electronic record for insurer or Fire Risk Assessment

Paper logbooks are lost, damaged or simply not available when insurers or fire risk assessors ask to see them. We maintain all test records digitally and provide immediate access on request.

04

Manual testing across a large industrial or multi-floor building

Torch testing individual non-addressed luminaires across a large premises is time-consuming and produces a compliance record that is difficult to defend. DALI-2 addressed systems automate this entirely — we can retrofit addressed modules into existing systems where the full system replacement is not warranted.

NHS
Eric Wright Group
Lancaster University
Bowmer + Kirkland
Conlon Construction
Casey
Barnfield
Caddick
Northern Care Alliance
Manchester Airports Group
NHS
Eric Wright Group
Lancaster University
Bowmer + Kirkland
Conlon Construction
Casey
Barnfield
Caddick
Northern Care Alliance
Manchester Airports Group

Technical detail

Standards & compliance

  • BS EN 50172 — emergency escape lighting systems
  • BS 5266 Part 1 — emergency lighting of premises
  • BS 5266 Part 7 / EN 1838 — illuminance requirements
  • IEE Wiring Regulations — emergency circuit requirements
  • Fire Risk Assessment interface and evidence provision

Test types & frequency

  • Monthly function test (minimum BS EN 50172 requirement)
  • Annual 3-hour duration test
  • 6-monthly intermediate duration test (certain occupancies)
  • DALI automated test scheduling and result logging
  • Battery condition monitoring and replacement prediction

Certificates & records

  • Emergency Lighting Design Certificate (ELDC)
  • Periodic inspection and test certificate
  • Duration test pass/fail certificate
  • Digital logbook and maintenance record system
  • Addressable system print-outs and electronic logs

Remedial follow-up

  • Failed luminaire replacement and re-test
  • Battery replacement on failure or degradation
  • Exit sign replacement and resiting
  • Circuit investigation for persistent test failures
  • Re-certification following remedial works
Con-Tec Solutions — emergency lighting testing and certification

The Numbers

Duration test standard

3hr

Annual 3-hour full duration test of every luminaire, witnessed and certified to BS EN 50172.

Monthly function tests per year

12×

Monthly function tests are the minimum required by BS EN 50172 — we carry them out and record each result digitally.

Automated test logging available

DALI

DALI-2 addressed systems automate the test cycle and produce electronic records — eliminating manual torch walks across large premises.

Why specify Con-Tec

Compliance Records That Hold Up to Scrutiny

01

Pre-test condition surveys

We identify aged batteries and failed luminaires before the formal annual test — so your duration test produces a pass certificate, not a remedial schedule.

02

Digital records accessible on demand

All test results, certificates and maintenance records held digitally — available immediately for insurer, Fire Risk Assessor or regulatory inspection.

03

DALI addressed system expertise

We design, commission and service DALI-2 addressed emergency systems — and can retrofit addressed modules into existing systems to automate the test cycle.

04

Remedial works on the same visit

Where failed luminaires or batteries are found during testing, we carry out the replacement on the same visit and re-test before leaving — so the system is compliant at the close of every service call.

01

Condition Survey & Baseline

Full luminaire and battery condition survey, producing a documented baseline and establishing the digital test record from the first visit.

02

Monthly Function Tests

Monthly attended or DALI-automated function tests, with digital results recorded and any failures reported immediately.

03

Annual Duration Test

Annual 3-hour duration test carried out, witnessed and certified — with battery and luminaire replacements completed on the same visit if required.

04

Compliance Report & Certificate

Annual compliance report and duration test certificate issued and added to the digital record — with recommendations for the next testing period.