Con-Tec Solutions

Testing & Compliance Service

PAT Testing

Portable appliance testing (PAT) to the IET Code of Practice — systematic testing, pass/fail labelling, digital asset records and compliance reports for commercial, industrial and public sector premises.

What portable appliance testing actually has to deliver

01

A large asset estate with no testing record

Premises with hundreds or thousands of portable appliances require a systematic programme to produce and maintain a compliant test record. We plan the testing programme, produce a full asset register and provide digital records from day one.

02

Testing that disrupts the working day

PAT testing across a busy commercial or industrial premises requires coordination with the site manager to minimise disruption. We work around operational hours, test in defined zones and hand each area back before moving to the next.

03

Failed appliances that need to be tracked to disposal

A fail result means the appliance must be removed from use immediately. We label, quarantine and report every failed item, with a written record suitable for insurance or HSE purposes.

04

No basis to set re-testing intervals

The IET Code of Practice recommends re-testing intervals based on equipment class, environment and use pattern — not a fixed annual cycle. We provide a risk-based recommendation for each equipment category so your testing programme is proportionate to actual risk.

NHS
Eric Wright Group
Lancaster University
Bowmer + Kirkland
Conlon Construction
Casey
Barnfield
Caddick
Northern Care Alliance
Manchester Airports Group
NHS
Eric Wright Group
Lancaster University
Bowmer + Kirkland
Conlon Construction
Casey
Barnfield
Caddick
Northern Care Alliance
Manchester Airports Group

Technical detail

Standards & guidance

  • IET Code of Practice for In-Service Inspection and Testing of Electrical Equipment
  • Health and Safety at Work Act 1974
  • Provision and Use of Work Equipment Regulations 1998
  • Electricity at Work Regulations 1989
  • Employer's Liability insurance compliance

Test types

  • Visual condition inspection
  • Earth continuity test (Class I equipment)
  • Insulation resistance test
  • Substitute / touch leakage current test
  • Flash / dielectric strength test where applicable

Equipment categories

  • Class I earthed equipment (power tools, kettles, monitors)
  • Class II double-insulated equipment
  • IT equipment and desktop computers
  • Extension leads and multi-way adapters
  • Industrial portable equipment and welding sets

Reporting & records

  • Pass/fail PAT labels applied at point of test
  • Digital asset register with barcode/asset number
  • Full test report with results per item
  • Failed item quarantine and removal log
  • Risk-based re-test interval recommendation
Con-Tec Solutions — portable appliance testing

The Numbers

Code of Practice compliant

IET

All testing carried out in accordance with the IET Code of Practice for In-Service Inspection and Testing of Electrical Equipment.

Digital records

100%

Every asset tested generates a digital record — accessible immediately for insurer, HSE inspection or internal audit.

Contact for the programme

1pt

A single Con-Tec engineer manages the full testing programme and asset register from first visit through to final report.

Why specify Con-Tec

Testing That Produces a Record You Can Use

01

Full asset register from the first visit

We build the asset register as we test — so from the moment the programme begins, you have a documented baseline for every portable appliance in the premises.

02

Minimal operational disruption

Zone-by-zone testing, coordinated with the site manager and planned around operational hours, so the testing programme runs around the business — not the other way around.

03

Failed appliance management

Every failed item is labelled, quarantined and reported at point of test — with a written record that satisfies insurance and HSE requirements.

04

Risk-proportionate re-test intervals

We apply IET Code of Practice risk-based methodology to recommend re-test intervals by equipment category — so your testing programme is proportionate and defensible.

01

Programme Planning

Asset estate scoped, zone schedule agreed with the site manager and access arrangements confirmed before testing begins.

02

Visual Inspection

Systematic visual condition check of every portable appliance, cable and plug before instrument testing commences.

03

Instrument Testing

Earth continuity, insulation resistance and leakage tests carried out to IET Code of Practice requirements, with digital results recorded per asset.

04

Report, Labels & Asset Register

Pass/fail labels applied, failed items quarantined, full test report and asset register submitted in digital format within 5 working days.

1 / 4

What our clients say

Con-Tec consistently meets the rigour our estates teams expect. Their compliance documentation, site discipline and turnaround on remedial works are exactly what large-scale healthcare contracts require.

Get a Quote

Ready to Start a Project?

We respond to every commercial and industrial enquiry within one working day. Share your scope and programme and we'll come back with lead engineers, approach and a clear cost envelope.

PAT Testing | Testing & Compliance | Con-Tec Solutions